Bnc 1105 Universal Counter Uživatelský manuál Strana 108

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 197
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 107
108
108108
108
Note
The recalculation is done automatically when any change is made to any of
the :CALCulate[1|2] commands when :CALC:IMM:AUTO ON.
:CALCulate[1]:IMMediate?
Queries the results of the new calculation.
Note
As the commands INIT:CONT OFF and CALCulate[1]:IMMediate:AUTO OFF are inputted,
the command :CALCulate[1]:IMMediate? is just valid.
:CALCulate[1]:IMMediate:AUTO <Boolean>
Sets if the re-calculation will automatically be done whenever there’s any change made
to any of the :CALCulate[1|2] commands.
When it is set to OFF, the :CALCulate[1|2] command produces new results when the
command is executed, even when new data is not acquired. And this allows the user to
have the new results on the same current data right after new configuration changes.
Return
An ASCII-encoded byte. 0 means OFF, and 1 means ON.
Notes
Affects all the recalculation command settings.
This will be set to OFF after the counter has been turned off or a remote interface
reset.
:CALCulate[1]:MATH[:EXPRession]:CATalog?
Queries the defined equation name.
Return
Returns the string “SCALE_OFFSET”.
:CALCulate[1]:MATH[:EXPRession][:DEFine]?
Queries the equation used in the calculation.
Return
Zobrazit stránku 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 196 197

Komentáře k této Příručce

Žádné komentáře