Strany 1 - 400 MHz Universal Counter

MODEL 1105 400 MHz Universal Counter With 6GHz in CHANNEL 3 User’s manual Printed date: 6/2011 Version: 1.04

Strany 2 - Table of Contents

10101010 1.7 Inspection The product package is supplied with the following items:  One MODEL 1105 [224 (W) x 107 (H) x 380 (D) mm with the fro

Strany 3

100100100100 B. Preset Values and Save/Recall Information Value at *RST ( GPIB Reset ) In Save/Recall In non-volatile memory Input impedanc

Strany 4

101101101101 C. General Specifications Item Limitation & description Power Supply Voltage 100V/240V±10% 50Hz~60Hz±10% 100V/120V±10% 400

Strany 5 - General Information

102102102102 D. Remote Interface Reference D.1 Introduction to the SCPI Language SCPI (Standard Commands for Programmable Instrume

Strany 6 - 1.2 Warranty Information

103103103103 SENSE, sens, and Sens are all acceptable. Other forms, such as SEN and SE, will generate an error. A vertical bar ( | ) sep

Strany 7 - 1.3 Precaution of Operation

104104104104 Use a colon and a semicolon to link commands from different subsystems. For example, in the following command string, an error is

Strany 8 - 1.5 Safety Information

105105105105 keyword is separated from the first parameter by a blank space. Use a semicolon (;) to separate multiple commands as shown below:

Strany 9 - 1.6 Symbols and Terms

106106106106 DISPlay:TEXT “CALC2” D.2 Command Reference :ABORt Aborts any measurement in progress as quickly as possible. Notes  When

Strany 10 - 1.7 Inspection

107107107107  When using ASCii format, numeric data is transferred as ASCII bytes in <NR3> format. The number of significant

Strany 11 - 1.8 Options and Accessories

108108108108 Note  The recalculation is done automatically when any change is made to any of the :CALCulate[1|2] commands when :C

Strany 12 - Overview

109109109109  A sequence of ASCII-encoded bytes(“SENS”*SCALE+OFFSET) terminated by a new line and EOI. Note  It should be the last query i

Strany 13

11111111 1.8 Options and Accessories The following options and accessories are available from Berkeley Nucleonics Corporation for use with th

Strany 14 - 2.1.2 To Replace the Fuse

110110110110 :CALC2:LIM:FCO :CALC2:LIM:PCO :CALC3:… Note  The re-calculation is done automatically when any change is made to any

Strany 15

111111111111  This will be set to ON after the counter has been turned off or a remote interface reset.  When this is set to ON, the f

Strany 16

112112112112  If the current measurement function is Totalize or Voltage Peaks, a “0” will be returned and error -221 will be gen

Strany 17

113113113113 generated.  If the current measurement function is Totalize or Voltage Peaks, a “0” will be returned and error -221

Strany 18 - 2.2.1 The Front Panel

114114114114  A fail will be returned if the result is less than the lower limit, but when the result is equal to the lower limit, the counter

Strany 19

115115115115 digits range from 1 to 15, depending on the resolution. Notes  The statistics operation should be enabled (:CALC3:AVER[:STATe] O

Strany 20 - 2.2.2 The Rear Panel

116116116116 Return  Numeric data transferred as ASCII bytes in <NR1> format. Notes  If the statistics operation is not enabled (:CAL

Strany 21

117117117117 significant digits will range from 1 to 15, depending on the resolution. Notes  Be sure to enable the statistics operation befo

Strany 22 - Making Measurements

118118118118 (:CALC2:LIM:FCO, :CALC2:LIM:PCO).  When the display is not able to show all of the significant digits of this value, the displaye

Strany 23

119119119119  It will be returned to 0 after the counter has been turned off or a remote interface reset.  When this is on, only the measurem

Strany 24 - 3.3 Time Interval Measurement

121212122 Overview This chapter will give you an overview of the MODEL 1105’s basic features and guide you through the basics of the M

Strany 25 - 3.4 Period Measurement

120120120120 Notes  The security state is stored in non-volatile memory and is unaffected by power-on, save/recall or *RST.  The

Strany 26

121121121121  A string with the form of “<function> <parameter> [,<source list>]” is returned.  If there is not a

Strany 27

122122122122 Return  A single ASCII-encoded byte. 0 means that the result display is in enabled and 0 means that the menu display is enable

Strany 28 - 3.6 Pulse Width Measurement

123123123123  A sequence of ASCII-encoded byte: COMM or DPO. Note  This value is stored at non-volatile memory, so it will not change after

Strany 29 - 3.7 Duty Cycle Measurement

124124124124 first. Note  Sending this command while a measurement is in progress will hold off further commands from being ex

Strany 30

125125125125 Return  A single ASCII-encoded byte. 0 means AUTO OFF and 1 means AUTO ON. Note  This will be set back to AUTO OFF after *RS

Strany 31 - 3.8 Totalize Measurements

126126126126  The beginning of the first measurement caused by setting :INIT:CONT ON sets the pending Operation Flag to true. The pending Oper

Strany 32 - 3.9 Phase Measurements

127127127127 receives :INIT[:IMM].  When :CALC2:LIM:CLE:AUTO is ON and whenever the counter receives :INIT:CONT ON command, it : o Inv

Strany 33

128128128128 Sets or queries the state of the low-pass filter. Return  A single ASCII-encoded byte. 0 means OFF and 1 means ON. Note  Thi

Strany 34

129129129129  Numeric data transferred as ASCII bytes in <NR3> format with six significant digits.  The value returned is 50. The Co

Strany 35 - Front Panel Operations

13131313 Figure 2-1 Step 2 (Pull out the handle) When the handle is turned up to 90˚ with the universal counter, please pull out the handle from

Strany 36 - 4.2 Key Functions

130130130130 :MEASure[:SCALar][:VOLTage]:FALL:TIME? [<lower_reference> [,upper_reference>]][,(@1)] Sets the measurement arming to

Strany 37 - Stop/Single)

131131131131 specified value. When they are specified in voltage, auto-trigger is disabled and the trigger level is the specified v

Strany 38 -  Auto Arming

132132132132 Resolution <resolution> should use a mantissa of 1.0 and be an even power of 10 <resolution> Ch3 Default Value which

Strany 39

133133133133 <source list> Default (@1) Range (@1)|(@2) :MEASure[:SCALar][:VOLTage]:MINimum? [(@1)|(@2)] Measures voltage minimum. <

Strany 40 -  Digits Arming

134134134134 Voltage range -5.125V to 5.125V for ×1 attenuation -51.25V to 51,25V for ×10 attenuation Voltage resolution 0.0025V for ×1 attenu

Strany 41

135135135135 The Channel 1 and Channel 2 share the same trigger setting so that the measurement channel has auto-trigger enabled at 50% with a

Strany 42

136136136136 Return  Numeric data transferred as ASCII bytes in <NR1> format, which is 21.  The response is one greater than the max

Strany 43

137137137137 Queries the current measurement results of the :SENSe commands (no scale or offset applied). Return  Result is formatted acco

Strany 44

138138138138 Return  The “100”, “50” or “0” PCT is returned. Note  As the command *RST is executed, the noise immunity will be set to 50

Strany 45

139139139139 Sets or queries the percentage of the peak-to-peak range of the signal at which the instrument automatically triggers. The range

Strany 46 - 4.4 Setting Scale and Offset

14141414Position 2 The adjusted position is for operation as shown in Figure 2-4. Figure 2-4 Position 3 The carrying position shows in Fig

Strany 47 - is then

140140140140 in volts as units. Note  The returned value is 0, and the unit is volts. [:SENSe]EVENt3:SLOPe? Queries which edge of channel 3

Strany 48 - 4.5 Limits Operations

141141141141 interface reset. [:SENSe]:FREQuency:ARM:STOP:DIGits <Numeric value> Sets or queries the resolution in terms of digits used

Strany 49

142142142142 [:SENSe]:FREQuency:ARM:STOP:TIMer <numeric value> [S] Sets or Queries the gate time used in arming Period, Frequency and Fr

Strany 50 - 4.6 Statistics Operations

143143143143  Single ASCII-encoded byte. 0 means OFF and 1 means ON. Notes  This will be set to ON after the counter has been turned off o

Strany 51

144144144144 the sensor function is frequency on channel 1, the returned string will be “FREQ”. If the sensor function is frequency on ch

Strany 52 - 4.8 Trigger Setting

145145145145 Sets or queries the start arm for Phase measurements. Return  A sequence of ASCII-encoded bytes. IMM means Immediate an

Strany 53

146146146146 [:SENSe]:ROSCillator:SOURce:AUTO <Boolean> Sets or queries the state of the auto-specifying reference timebase. With this on

Strany 54

147147147147 front panel gating settings and the interface command parameters, please refer to the TINT table in Chapter 5.4. [:SENSe]:TINTe

Strany 55

148148148148 Internal 1 is used.  This command does not apply on Rise/Fall time, Duty cycle or Pulse width measurements.[:SENSe

Strany 56

149149149149 negative edge. Notes  This will be set to Positive after the counter has been turned off or a remote interface reset.  This

Strany 57

15151515 Figure 2-6 Step 2 (Pull out the handle) When the handle is turned up to 90˚ with the universal counter, please pull out the handle from

Strany 58 - 4.10 Utility Operations

150150150150  A sequence of ASCII-encoded bytes. IMM means Immediate, INT means Internal2 and TIM means Timer. Note  This will be set to

Strany 59 - <Boolean>,<NRf>

151151151151  This command only applies when [:SENSe]:TOT:ARM[:STAR]:SOUR EXT is used. [:SENSe]:TOTalize:ARM[:STARt]:SOURce IMMediate EXTe

Strany 60

152152152152 reset.  When the staring and the stopping points are both set to immediate, the command :INIT[:IMM] can be used to s

Strany 61 - 4.11 Display Tips

153153153153  A USB or DB9 message will be returned. Note  As the command :SYSTem:COMMunicate:SERial:SOURce USB is executed, users

Strany 62 - 4.11.2 Get HELP on ANY KEY

154154154154 :SYSTem:KEY <numeric value> This command simulates the pressing of a front-panel key. The parameter <numeric value> i

Strany 63 - Technical Support

155155155155 :SYSTem:KEY:LOG? Queries all the entries in the Key Queue. Return  Numeric data transferred as ASCII bytes in <NR1> form

Strany 64

156156156156 I/O mode is compatible. :SYSTem:UTILity:IO:MODE NATive COMPatibility To set and query the IDN string, the NATive can be selected

Strany 65 - Remote Interface Operations

157157157157 Return  The format of the response is according to the specification made in :FORMat[:DATA] ASCii|REAL command.  If using the

Strany 66

158158158158 :TRIGger:COUNt:AUTO <Boolean> Sets or queries the control over the number of measurements taken when :INITiate[:I

Strany 67

159159159159  This command does not clear saved settings or any data memories.  This command will clear any displayed error messages. *DDT&l

Strany 68

16161616 Figure 2-8 Step 4 Put the counter upside-down on the worktable and release the srew under a warranty seal as shown in Figure

Strany 69

160160160160 Queries the Standard Event Status Enable Register. Return  Numeric data transferred as ASCII bytes in <NR1> format. Note

Strany 70

161161161161 counter has been turned off or upon the transition of the measurement cycle from measuring to idle. *OPC? A response is genera

Strany 71

162162162162 *WAI :CALibration:DATA :CALibration:SECurity:CODE :CALibration:SECurity:STATe :CONFigure? :DISPlay:ENABle :DISPlay:MENU[:STATe] :D

Strany 72

111163636363 resolution is 1. *SRE? Queries the Service Request Enable Register. Return  Numeric data transferred as ASCII bytes in <NR1&

Strany 73

164164164164 Starts an internal self-test and returns a response indicating if there is any error found in the self-test. Return  Numeric dat

Strany 74 - [:IMMediate]

165165165165 [:EXPRession] :CATalog? [:DEFine]? :NAME :SELect SCALE_OFFSET :STATe <Boolean> :CALCulate2 :FEE

Strany 75 - The [:SENSe] command

166166166166 :CURRent? :TYPE MAXimum MINimum SDEViation SCALar or MEANDELTa | ALLAN :LFILter :STATe <Boolean> :LOWer

Strany 76 - The :TRACe Commands

167167167167 :INPut[1|2] :ATTenuation :COUPling AC DC :FILTer [:LPASs] [:STATe] <Boolean> :FREQuency? :IMPedance

Strany 77

168168168168 :SOURce IMMediate EXTernal :TIMer <numeric value> [S] :DIGits <numeric value> :EXPected[1|

Strany 78 - Commands SYSTEM-RELATED

169169169169 :EXTernal :FREQuency? :TINTerval :ARM :ESTART :LAYer2 :SLOPe POSitive NEGative

Strany 79

17171717 Figure 2-10 Step 6 Loose the fuse by a flat-head screwdriver as shown in Figure 2-11. Replace a new one conforming to the specifi

Strany 80

170170170170 :TIMer <numeric value> [S] :SYSTem :COMMunicate :SERial :SOURce USB DB9 :CONTrol :DTR OFF

Strany 81 - Manual Calibration Procedures

171171171171 E. About Application Programs This section provides a brief description for each MODEL 1105 sample collection. Using CONFigu

Strany 82

172172172172 printf ("Error Initializing NI-VISA..."); return 0; } stat = viFindRsrc (defaultRM, "USB[0-9]::0x164E::

Strany 83

173173173173 stat = viWrite(sesn, (unsigned char *)("INP1:ATT 1"), 10, &ret); stat = viWrite(sesn, (unsigned char *)("IN

Strany 84

174174174174 // stat = viWrite(sesn, "FREQ:ARM:STOP:SOUR Ext", 22, &ret); // stat = viWrite(sesn, "FREQ:ARM:STOP:SOUR TIM&

Strany 85 - (Including External ARM)

175175175175 { ViStatus stat; /* For checking errors */ ViSession defaultRM; /* Communication channels */ ViSession sesn; /* Communicatio

Strany 86

176176176176 } stat = viFindNext (flist, rsrcName); //Setting Process Timeout stat = viGetAttribute(sesn, VI_ATTR_TMO_VALUE, &tmo);

Strany 87

177177177177 /*----------------------------------------------------------------------------------*/ /*------------------------------- Period m

Strany 88 - Error Messages

178178178178 /*-------------------------------- Gate Auto -------------------------------------*/ // stat = viWrite(sesn, "TINT:ARM:ESTAR

Strany 89

179179179179 } Example 3 Volt Peak measurement // Volt_Peak.cpp : Defines the entry point for the console application. #include "stdafx.h

Strany 90

18181818assemble correctly with the case, stack up the counter, whose front panel should be towards down, on the rear bumper as shown in

Strany 91 - 7.2 Execution Errors

180180180180 stat = viOpen (defaultRM, rsrcName, VI_NULL, VI_NULL, &sesn); if (stat < VI_SUCCESS) { printf ("Could not op

Strany 92 - 7.4 Query Errors

181181181181 &ret); /*----------------------------- CH2 Input Condition -----------------------------*/ stat = viWrite(sesn, (unsigned ch

Strany 93 - 7.5 Counter-Specific Errors

182182182182 return 0; } Example 4 Other Measurement // OtherMeas.cpp : Defines the entry point for the console application. #include "

Strany 94 - Appendix

183183183183 stat = viOpen (defaultRM, rsrcName, VI_NULL, VI_NULL, &sesn); if (stat < VI_SUCCESS) { printf ("Could not o

Strany 95

184184184184 stat = viWrite(sesn, (unsigned char *)("EVEN1:LEV:ABS:AUTO ON"), 21, &ret); /*----------------------------- CH2 In

Strany 96 - Base Selection

185185185185 /*------------------------------- Total CH1 measure ----------------------------*/ // stat = viWrite(sesn, "CONF:TOT (@1),(@

Strany 97

186186186186 #include "stdio.h" int main(int argc, char* argv[]) { ViStatus stat; /* For checking errors */ ViSession defaultRM; /

Strany 98

187187187187 { stat = viGetAttribute (sesn, VI_ATTR_INTF_INST_NAME, intfDesc); printf ("Resource %s, Description %s\n", rsrcNa

Strany 99 - A.1 RMS Resolution

188188188188 stat = viWrite(sesn, (unsigned char *)("EVEN2:LEV:REL 50"), 16, &ret); stat = viWrite(sesn, (unsigned char *)(&quo

Strany 100

189189189189 stat = viWrite(sesn, (unsigned char *)("TRAC:DATA OFFSET,5MHz"), 21, &ret); /*-------------------------------------

Strany 101 - C. General Specifications

19191919 Figure 2-6 1. Power & Display (in the purple area):  Power: Turn on/off the MODEL 1105 universal counter.  Help: Instruction f

Strany 102

190190190190 ViFindList flist; /* To hold list of resources */ char readin[128]=""; int tmo; printf("\n ###### Start C++ E

Strany 103

191191191191 //send reset command '*RST' -- reset MODEL 1105 stat = viWrite(sesn, (unsigned char *)("*RST"), 4, &ret)

Strany 104

192192192192 // stat = viWrite(sesn, "CONF:FREQ:RAT (@1),(@2)", 23, &ret); // stat = viWrite(sesn, "CONF:FREQ:RAT (@1)

Strany 105

193193193193 /*----------------------------------------------------------------------------------*/ /*----------------------------- Read From

Strany 106 - D.2 Command Reference

194194194194 int tmo; printf("\n ###### Start C++ Example program. ######\n"); printf(" We check the Counter on USB port

Strany 107

195195195195 //send Clear command '*CLS'-- Clear MODEL 1105 status register stat = viWrite(sesn, (unsigned char *)("*CLS&quo

Strany 108

196196196196 /*----------------------------------------------------------------------------------*/ /*-------------------------------- Gate Ti

Strany 109 - The command :CALCulate2

197197197197 /*----------------------------- Read From Device -------------------------------*/ stat = viWrite(sesn, (unsigned char *)("

Strany 110

2222 Table of Contents 1 GENERAL INFORMATION ... 5

Strany 111

202020205. Channel condition buttons and connectors (in the black area):  CH1: Channel 1 condition control key and connector.  CH2:

Strany 112

212121213. External 10 MHz Output Terminal 4. LAN Interface Connector 5. GPIB Interface Connector 6. USB Interface Connector 7. Power cord

Strany 113

222222223 Making Measurements This chapter guides users how to make some basic measurement via the MODEL 1105 universal counter, and to get to kn

Strany 114

232323236. Press STOP/SINGLE button to make single measurement or to stop continuous measurements. Remote Interface Command Use the following

Strany 115

24242424the trig Sens. f. Use Show Status button to check the conditions of Input, Volt, Stats and Limit. g. Use Save&Recall button to save

Strany 116

25252525b. Use Scale&Offset button to set the scaling and offset parameters if it’s needed (refer to Ch.4.4). c. Use Limit Modes button se

Strany 117

26262626To measure period 1. Connect your signal source to channel 1. 2. Press TIME&PERIOD button. 3. Press the softkey under Period

Strany 118

272727273.5 Rise/Fall Time Measurement Auto triggering is enabled by default for rise/fall time measurmenet, and it automatically identifies the 1

Strany 119

28282828[:SENSe]:FUNCtion[:ON] “[:][XNONe:]FTIMe [1]” Or :CONFigure[:SCALar][:VOLTage]:RISE:TIME [(@1)] :CONFigure[:SCALar][:VOLTage]:RTIMe [(@1)]

Strany 120 - The Command :CONFigure

29292929needed (refer to Ch.4.6). e. Use the selections in the CH1 to set the input conditions and the trig Sens. f. Use Show Status button to c

Strany 121

3333 4.3 GATE & EXTERNAL ARM OPERATIONS ... 38 4.4 SETTING SCALE AND

Strany 122

30303030slopes settings (refer to Ch.4.8). To measure Duty Cycle 1. Connect your signal source to channel 1. 2. Press OTHER MEAS button. 3

Strany 123

31313131:MEASure[:SCALar][:VOLTage]:PDUTycycle? [(@1)] 3.8 Totalize Measurements Totalize measurement counts and displays the number of

Strany 124

32323232Or :CONFigure[:SCALar][:VOLTage]:TOTalize:CONTinuous [(@1)] :CONFigure[:SCALar][:VOLTage]:TOTalize:TIMed [(@1)] :READ[[:SCALar][:VOLTage]:

Strany 125

33333333the trig Sens. f. Use Show Status button to check the conditions of Input, Volt, Stats and Limit. g. Use Save&Recall button to save

Strany 126

34343434Vmax (positive peak), Vmin (negative peak), Vc (average from positive and negative peak) or Vpp (peak-to-peak). c. Use the select

Strany 127

35353535 4 Front Panel Operations This chapter will guide you through different ways of configuring measurement functions. It contain

Strany 128

36363636 Figure 4-3 Figure 4-4

Strany 129 - The Commands :MEASure?

37373737cancel the changes, press the softkey under CANCEL. 4.2.2 Measurement Control Keys (Run and Stop/Single) There are two measurement mode

Strany 130

383838384.3 Gate & External Arm operations The MODEL 1105 provides four arming modes: auto, time, digits and external. The descriptions are

Strany 131

39393939measurements. For totalize measurements, the counter starts to count whenever Run button or Stop/Single button is pressed. Figure

Strany 132

4444 7.4 QUERY ERRORS ... 92 7.5 COUNT

Strany 133

40404040 Digits Arming Under the Digits Arming mode with the range from 3 to 15 as shown in the Figure 4-10 for the available measurement

Strany 134

41414141negative, auto and time. This is to specify how measurement should stop. Positive and negative specifies the slope of the stop arm signal.

Strany 135

42424242Remote Interface Command Auto arming: [:SENSe]:TINTerval:ARM:ESTART:LAYer2:SOURce IMMediate External arming: [:SENSe]:TINTerval:ARM:EST

Strany 136 - The Command :SENSe

43434343toggle between positive and negative. This is to specify the slope of the start arm signal. Press the softkey under STOP to toggle between

Strany 137

44444444according to purposes. If External Arming is selected, users can define the delay time and other settings by pressing the softkey under *D

Strany 138

45454545[:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:SOURce INTernal2 [:SENSe]:TINTerval:ARM:ESTOP[:LAYer[1]]:TIMer <numeric_value> [S] [:SENSe]:

Strany 139

46464646 4.4 Setting Scale and Offset The MODEL 1105 provides the option of performing scaling and offset calculations on the measurement result

Strany 140

47474747To Enable/Disable Math Calculation with Scale and Offset 1. Press SCALE&OFFSET button. 2. Press the softkey under Scale or Offs to d

Strany 141

48484848softkey under Cancel to withdraw the changes. Remote interface command Use the following command to specify the value of Offset: :TR

Strany 142

49494949To set upper or lower limit 1. Press LIMIT MODES button. 2. Press the softkey under UPPR to select upper limit or under LOWR to select l

Strany 143

55551 General Information This section contains general information about BERKELEY NUCLEONICS CORPORATION MODEL 1105 Universal Counter. The

Strany 144

50505050To display graph for limit testing result The counter display Limit Testing results in a graph where a circle within two vertical bars r

Strany 145

51515151Allan.  To display measurement: press the softkey under SHOW to toggle through the options until MEAS appears.  To set numbe

Strany 146

52525252Procedures for setting up the input conditions are identical for both channels.  To Set Input Impedance: press the softkey und

Strany 147

53535353Sensitivity at a particular frequency is the lowest amplitude signal to trigger the counter for counting. The amplifier gain an

Strany 148

54545454Figure 4-16  To set trigger level: press the softkey under LEVEL and use the numeric keypad or arrow keys to enter a desired value as

Strany 149

55555555LOW, MED (medium) and HIGH as shown in the Figure 4-21. Figure 4-21  To set Com.: The setting is enabled only by using Time Interval a

Strany 150

565656562. Press TIME&PERIOD button. 3. Use the softkey under (INTVL 1 to 2) to select interval measurement 4. Press CH1 (or CH2) button to

Strany 151

57575757 Figure 4-23 Remote Interface Command *SAV <Nrf> To recall measurement setting 1. Press SAVE&RECALL button. 2. Use the softk

Strany 152 - The Commands :SYSTem

58585858To Power on Recall 1. Press Save & Recall button. 2. Press the softkey under Save to select the memory number from 1 to 20 for stock

Strany 153

59595959 softkey under Save.). For more calibration information, please check the List 4-1. 5. Press the softkey under Run Cal when everything

Strany 154

6666 Multi-parameter display of results.  Optional third channel that provides measurements up to 20 GHz.  Easy-to-use shortcut keys.  Eas

Strany 155

60606060time-out limit, the counter will send a not-a-number value to the computer. For this purpose, the counter can prevent ke

Strany 156 - The Commands :TRACe

61616161TimeBase Source Follow the following instruction to select TimeBase source: 1. Press UTILITY button. 2. Use the softkey under TimeBase

Strany 157

62626262 4.11.1 View Remote Command Error Via the display tips, users will easily view remote command error. The operation procedures are in the

Strany 158

63636363Default state resetting”. Teaching instruction will be there, such as 1: Press [Save&Recall]. 2: Press “PwrOn Recall” to select

Strany 159

64646464for technical support. 3. Press the softkey under Done to return to the operation mode.

Strany 160

656565655 Remote Interface Operations The MODEL 1105 supports three interfaces for remote access: USB, LAN and GPIB (IEEE-488). USB and LAN are b

Strany 161

666666663 D+ Green Limit Test Fail 4 GND Black GND Figure 5-1 Note: The Pass/Fail Output can’t be used on Volt Peak and Totalize. 5.2 Pass/Fa

Strany 162

67676767 NUCLEONICS CORPORATION to remotely control the universal counter through USB, LAN or GBIP interface. To set up the USB interface The

Strany 163

68686868 Note: The MODEL 1105’s LAN supports the environments including Web Server and Java (TM) SE Runtime 6 (Update 1) or up. To configure LA

Strany 164

69696969255. The procedure is described as follows. To set IP address, network mask or gateway 1. Press the softkey under DHCP to turn off DHCP.

Strany 165

7777 The remedies provided herein are the buyer’s sole and exclusive remedies. BERKELEY NUCLEONICS CORPORATION shall not be liable for any

Strany 166

70707070connected and interface is properly configured as described in Ch.5.1. The SCPI commands available for the MODEL 1105 are listed below for

Strany 167

71717171 The MEASure? Command Although it does not offer much flexibility, using the command :MEASure? is the simplest way to program the Coun

Strany 168

72727272 [:VOLTage]:PHASe? [(@1),(@2)] [:VOLTage]:DCYCle? [<reference>][,(@1)] [:VOLTage]:PDUTycycle? [<reference>][,(@1)] [:VOLT

Strany 169

73737373 [:VOLTage]:PWIDth [<reference>][,(@1)] [:VOLTage]:NWIDth [<reference>][,(@1)] [:VOLTage]:INITerval [(@1),(@2)] [:VOLTa

Strany 170

74747474 [:VOLTage]:FTIMe? [:VOLTage]:PWIDth? [:VOLTage]:NWIDth? [:VOLTage]:INITerval? [:VOLTage]:PTPeak? [:VOLTage]:MAXimum? [:VOLTa

Strany 171

75757575 [:VOLTage]:RTIMe? [:VOLTage]:FALL:TIME? [:VOLTage]:FTIMe? [:VOLTage]:PWIDth? [:VOLTage]:NWIDth? [:VOLTage]:INITerval? [:VOLT

Strany 172

76767676:FREQuency:ARM:STOP:SOURce IMMediate|EXTernal|TIMer|DIGits :FREQuency:ARM:STOP:TIMer <numeric value> [S] :FREQuency:EXPected[1|2|3]

Strany 173

77777777 The COMMANDS CALCulate All commands :CALCulate perform mathematical operations on the measurements, but among those commands

Strany 174

78787878 :CALCulate3 :AVERage:ALL? :AVERage:CLEar :AVERage:COUNt <numeric_value> :AVERage:COUNt:CURRent? :AVERage:[:STATe] <Boolean> :

Strany 175

79797979:IDNStr <QUOTED STRING> Example: SYSTem:IDNStr “BERKELEY NUCLEONICS CORPORATION MODEL 1105,0,0,0” CALIBRATION COMMANDS The MO

Strany 176

8888 The patent and related documents for the equipment belong to BERKELEY NUCLEONICS CORPORATION. Any part of reproduction is illega

Strany 177

80808080*IDN? *OPC *OPC? *OPT? *RCL <NRf> *RST *SAV <NRf> *SRE <NRf> *SRE? *STB? *TRG *TST? *WAI

Strany 178

818181816 Manual Calibration Procedures The manual calibration is via the following procedures: UTILITY > CAL > Enter Security Code >

Strany 179

82828282Inp2. 2. Remove all sources on the counter. 3. Press the softkey under RunCal to do the calibration. Then, the counter’s display will sh

Strany 180

83838383 6.5 How to do the Gain Calibration via CH1 The Offset Calibration via CH1 is for checking DC +5V. Please do the following procedures

Strany 181

84848484 will disappear from the display as calibration is done. On the contrary, the NG message will show on the display as calibrat

Strany 182 - Example 4 Other Measurement

85858585 4. Adjust the voltage on the Agilent 33220A, and let the DMM displays +5.000V ±0.001V. 5. Remove the input source, from th

Strany 183

86868686 6.10 How to do the Time Interval Calibration The calibration is for Time Interval excluding the External ARM. Please do the followi

Strany 184

87878787 MODE/TRG > Pulse-Period > internal PLL. 6. Under the Agilent 81110A operation, press LEVELS and then Output1 and Output

Strany 185 - Example 5 Scale & Offset

888888887 Error Messages Errors are retrieved in first-in-first-out (FIFO) order. The first error returned is the first error that was s

Strany 186

89898989type. For example, numeric or string data was expected, but block data was received.  -105 GET not allowed A Group Execute Trigger was r

Strany 187

9999 The main power supply module contains a fuse rated 3.15A/250V. When replacing the fuse (BUSSMANN F3.15A250V), use only the same typ

Strany 188

90909090 -141 Invalid character data An invalid character was detected in the character data element.  -148 Character data not allowed A legal

Strany 189 - Example 6 Limit Modes

919191917.2 Execution Errors  -200 Execution error This is the generic syntax error if the Counter cannot detect more specific errors. This code

Strany 190

92929292missing Counter hardware. For example, the Channel 3 option was not installed.  -272 Macro execution error Indicates that a syntactic

Strany 191

939393937.5 Counter-Specific Errors  +2000 Offset calibration on channel 1 failed  +2001 Offset calibration on channel 2 failed  +2002 Gain

Strany 192

94949494Appendix A. Specification List This appendix contains the specifications of the MODEL 1105. It covers the AC, DC, Resistance, Tempe

Strany 193 - Example 7 Stats Modes

95959595Width (150 mVpp with optional rear connectors) >10 ns Pulse Width 50 mVpp to 10 Vpp (150 mVpp with optional rear connectors) Trigger

Strany 194

96969696 +25 dBm DC ±12V External Arm Input Specifications Signal Input Range LVTTL and TTL compatible Timing Restrictions Pulse Width >

Strany 195

97979797 Channel 1 and 2 Trigger Default setting is Auto Trigger at 50 % “Auto” Gate Time 0.1 sec STD CH 3 375 MHz to 6 GHz (0.166 ns to 2

Strany 196

98989898 Trigger Default setting is Trigger at 0 V Results Range 1.5 ns to 10E+15 Resolution 1 count Systematic Uncertainty ± 1 count Peak V

Strany 197

99999999A.1 RMS Resolution Rms (Typical) 100Hz 1KHz 10KHz 100KHz 1105 (10ms) 0.000000842 0.000003438 0.000013896 0.000067275 1105 (100ms) 0

Komentáře k této Příručce

Žádné komentáře